Accessories

Patient Breathing Circuits / CPAP Masks,

Single Patient Use, Disposable


P/N 58001 – Circuit, 6 foot (1.8 m), 15 / box
P/N 58011 – Circuit, 6 foot (1.8 m) with large CPAP mask & head strap, 10 / box
P/N 58021 – Circuit, 6 foot (1.8 m) with large CPAP mask, head strap & expiratory filter, 10 / box
P/N 58051 – Circuit, 8 foot (2.4 m), 15 / box
P/N 58202 – CPAP mask, medium, 20 / box
P/N 58208 – CPAP mask, small, 20 / box
P/N 58211 – CPAP mask, large, 20 / box
P/N 58210 – Bacterial / Viral Filter, main line or expiratory, 50 / box

SAFETY NOTE:  The patient circuits and CPAP masks are used to connect adult / pediatric patients to any Airon ventilator / CPAP system.  Only Airon manufactured patient breathing circuits are approved for use with pNeuton ventilators and the MACS CPAP System.

 

Safe-T-Vent Nebulizer Kit

P/N 58250 – 10 / box
The Safe-T-Vent nebulizer is designed to nebulize medications for inhalation in conjunction with the pNeuton Ventilator / MACS CPAP System and other positive pressure breathing devices.  The single use nebulizer can also be used as a stand alone medication nebulizer. This unique nebulizer system includes a spring-loaded seal built into the Safe-T-Vent; the seal allows the nebulizer to be removed while maintaining positive pressure.

 

Test Lung – 1 Liter

P/N 21002
A rigid wall Test Lung is ideal to test and demonstrate the performance of all Airon products.  Spontaneous breaths can only be properly simulated using a rigid wall test lung.

 

MACS Accessories

Travel Bag

P/N 21021
The Travel Bag holds MACS securely for transport and ensures it is ready for use.  The bag has a side pouch to store a patient circuit, a bright yellow reflective stripe, a hand carry strap and a shoulder strap.  As an added convenience a clear front panel protects the front panel while allowing the MACS to be operated in the bag.

 

Protective Boot

P/N 21025
The Protective Boot wraps around MACS to protect it from accidental falls.  MACS can be operated while in the boot.  A shoulder strap makes it very easy to carry.  The Pole Mount and Bed Rail Mount brackets can be used with the Protective Boot.

 

Pole Mounting Bracket

P/N 21040
The Pole Mounting Bracket allows the MACS to be firmly attached to a vertical pole, such as an IV pole.  Poles up to 1.25” (3 cm) can be accommodated.  MACS slides in and out of the bracket which allows portable use.  The bracket can be used with the Protective Boot.

 

Bed Rail Mounting Bracket

P/N 21041
The Bed Rail Mounting Bracket allows the MACS to be firmly attached to a horizontal tube, such as a bed rail.  Tubes up to 1.25” (3 cm) can be accommodated.  MACS slides in and out of the bracket which allows portable use.  The bracket can be used with the Protective Boot.

 

Ventilator Accessories

 

Mobile Stand

P/N 21001
The Mobile Stand is a 3 foot, 9 inch (1.2 m) tall, MRI compatible stand designed to hold the pNeuton ventilator, model S or A.  The five wheeled stand uses large 3 inch (7.6 cm) wheels to aid in stability and ease of movement.  Two “E” size cylinders can be securely mounted on the stand.  The ventilator attaches to the stand using a mounting plate which allows the user to slide the ventilator on and off the stand for transport.

 

Bed Rail Mount

P/N 21016 – Model A
P/N 21017 – Model S
The MRI compatible Bed Rail Mount will allow the pNeuton ventilators to hang from standard critical care bed rails and mobile stretchers.  The mount fits securely onto the top of the ventilator and provides a sturdy support during patient transport.

Travel Bag – pNeuton S

P/N 21020
The Travel Bag holds the ventilator securely and safely for transport.  The pNeuton can be operated while in the bag.  The clear front panel, held closed with Velcro, can be opened to make control adjustments and then closed for operation.  The bag has room for a patient circuit, a side pouch for masks or other items, a bright yellow reflective stripe, hand carry strap and a shoulder strap.

 

Remote Alarm

P/N 21031
The Remote Alarm is a battery powered alarm system used to connect the remote alarm outlet on the pNeuton model A ventilator.  The alarm will provide a visual and audible alarm when there is an alarm on the ventilator.  The alarm system can be used in the control room of MRI suites to alert caregivers of an alarm on the ventilator.  Manufactured by Phillips / Respironics as their part number 34003.  This alarm is not MRI compatible.

 

Remote Alarm Cable

P/N 21035 – 50 feet (15.2 m)
P/N 21036 – 100 feet (30.5 m)
The Remote Alarm Cable allows the pNeuton model A ventilator to connect to remote alarm systems.  It has BNC male – female connections.  These cables are MRI compatible.

 

Oxygen Supply Accessories


Oxygen Regulators

P/N 21051 – MRI compatible, high pressure DISS port only
P/N 21053 – 0 – 25 LPM barb outlet with high pressure DISS port
Regulators are used to connect Airon products to E or D size oxygen cylinders.  Part number 21051 is ideal for hospital and MRI use.  Part number 21053 provides a low flow barb and high pressure DISS outlet for EMS use (not MRI compatible).

Manifold System

P/N 21055 – with 2 regulators and check valves
P/N 21058 – with 2 manual shut off valves
The MRI compatible Manifold System is designed to allow the ventilator to be powered from either a wall source or one of two “E” oxygen cylinders.  The Manifold mounts onto the mobile stand and has three input DISS fittings and one output to the ventilator.  As oxygen enters any of the three input fittings it flows to the ventilator.  All systems include three 18 inch (0.5 m) and one 10 foot (3 m) high pressure oxygen hose.

  • The 21055 Manifold System comes packaged with 2 MRI compatible “E” cylinder regulators and one-way check valves.
  • The 21058 Manifold System is designed for use with oxygen tanks that have built-in regulators (eg. Airgas Walk-O2-Bout®) and includes 2 manual on / off valves.

High Pressure Oxygen Hose

P/N 21061 – 3 foot (0.9 m)
P/N 21068 – 8 foot (2.4 m)
P/N 21082 – 12 foot (3.7 m)
P/N 21069 – 30 foot (9.1 m)
P/N 21085 – 3 foot (0.9 m), coiled (extends to 15 foot – 4.6 m), not MRI compatible
The High Pressure Oxygen Hose is used to connect the pNeuton or MACS to an oxygen source.  Hoses are MRI compatible (except for P/N 21085) and have female DISS connections on each end.

 

Oxygen Quick Connect Couplers

P/N 21100 – Ohmeda style
P/N 21101 – Chemtron style
Quick Connect Couplers are used in ambulances to allow a quick change from an oxygen cylinder to a wall oxygen outlet.  Using an oxygen hose from a pNeuton or MACS with a matching quick connect fitting, the oxygen source can be unplugged from the tank with a quick twist and plugged into the wall source with minimal disruption of life support.  These couplers are not MRI compatible.

 

Oxygen 90 Degree Coupler

P/N  21102
A 90 degree elbow coupler to connect to the oxygen input of all products.  The coupler allows the oxygen hose connection to come out the bottom or side of the device.  It has male and female DISS fittings.  This coupler is not MRI compatible.

 

Oxygen Quick Connect Fittings

P/N 50347 – Ohmeda style
P/N 50348 – Chemtron style
Quick Connect Fittings are attached to standard high pressure oxygen hoses.  These fittings allow a quick attachment to a matching oxygen outlet without having to screw / unscrew a standard DISS connection.  The fittings are not MRI compatible.

 

Oxygen Cylinders

P/N 21071 – “E” size (680 L fill capacity), MRI compatible
P/N 21073 – “D” size (425 L fill capacity), with toggle valve, not MRI compatible
Portable high pressure oxygen cylinders for use with all products.

 

Clinical Resources

 

User Resource CD – Windows


P/N 97021 – Ventilators (English)
P/N 97022 – MACS CPAP (English)

These CDs are designed for physicians, nurses and respiratory professionals to learn how to use Airon products.  The CD will automatically boot on Microsoft Windows based computers, version 95 or above.  All files are in Adobe PDF, Adobe Reader (vr 5 or above) is required.  The following information is included on the CD:

  • Clinical training video with separate script (PN 97021)
  • Operators Manuals for both ventilators and/or MACS
  • PowerPoint presentations on how to use the ventilators, step by step
  • User training presentation script with check off sheet
  • Case study with tests
  • Frequently Asked Questions (PN 97021)
  • Clinical information on Work of Breathing, Oxygen Usage, Bi-Level Pressure Ventilation and NBC Filter Use (PN 97021)

 

MACS CPAP Educator Training CD – Windows

P/N 97023 (English)

This CD is designed for professional health care educators to train EMS / Ambulance personnel on the clinical usefulness of Mask CPAP.  The CD will automatically boot on Microsoft Windows based computers, version 95 or above.  All files are in Adobe PDF, Adobe Reader (vr 5 or above) is required.  The following information is included on the CD:

  • Respiratory Anatomy & Physiology module
  • Clinical Applications – CardioPulmonary Disease module
  • CPAP Mechanics module
  • CPAP Application Guidelines module
  • MACS CPAP System Operation module
  • CPAP Scientific Bibliography with copies of a few important citations
  • CPAP Protocols from across the USA

 

pNeuton A Clinical Training DVD

P/N 97025 (English)

DVD video on how to use the pNeuton model A ventilator.  This 8 minute video goes step by step on setting up and using the ventilator.  The DVD will play on standard DVD players (NTSC) or DVD reader equipped computers.

 

Operators Manuals – printed booklet

pNeuton Model S – English (P/N 97001), Spanish (P/N 97002), French (P/N 97003), German (P/N 97004)
pNeuton Model A – English (P/N 97011), Spanish (P/N 97012), French (P/N 97013), German (P/N 97014)
MACS CPAP – English (P/N 97031), Spanish (P/N 97032), French (P/N 97033), German (P/N 97034)